FedEx Packaging Test Standards for Parcel Shippers

By Lim Xu, Export Manager

FedEx packaging test standards, as described on the carrier's public distribution-testing page, are performance tests for packaged products in its networks. This article summarises what that page lists for smaller parcels, then stays with the compression check. It does not offer a drop or vibration tester, and it does not claim that we run FedEx-certified tests.

What the official FedEx page lists

FedEx publishes a distribution-testing page for packages in its Ground and Express small-parcel networks. The page describes performance testing for packages weighing less than 150 lb, with less than 165 inches combined length and girth, and it lists preconditioning, drop, compression and vibration among the checks.

That list is a carrier programme, not a single ASTM number. The official page also notes that additional ISTA, ASTM and NMFC distribution-package tests may be available. For the current sequence, limits and any fees, use the FedEx page and the documents it points to, not this article.

ISTA identifiers that are no longer current

ISTA previously published 6-Series procedures identified with FedEx. ISTA's public test-procedures page now states that those FedEx-A and FedEx-B procedures are no longer ISTA 6-Series tests. Do not treat a withdrawn ISTA identifier as the current instruction without checking ISTA and FedEx.

Where carton compression fits

Compression is one of the checks on that official list. In the laboratory, compression of a shipping container is commonly discussed under ASTM D642, with related ISO and TAPPI methods. Our article on box compression test standards compares those texts.

A carton compression tester can be used for a D642-type check on a box. Whether a given test setup matches a FedEx or ISTA sequence has to be read from the current official procedure and confirmed. That includes platen type, load, duration, and whether the box is empty or filled. This article does not copy those procedure details, and it does not state instrument capacities.

The KY-2 carton compression tester is the carton compression instrument on this site. It is not in our verified L1 capability list, so this article does not state its specifications. Please confirm with us whether a given method and package size can be run on it.

Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].

What this site does not cover in that sequence

Drop and vibration are also listed on the official FedEx page. This site does not present a package-drop tester or a transport-vibration table for sale in this article, and you should not treat a compression result as a substitute for those checks.

Preconditioning, when a procedure requires it, is a temperature and humidity condition of the packaged product, not a setting on a compression tester. Follow the official text for the atmosphere and the time.

If you need a full carrier or ISTA sequence, use a lab or a set of instruments that can run every step in that sequence. Our burst and compression testers collection is the product family for the compression and burst instruments on this site, not for a complete parcel-shipment programme.

What a shipper should take to a test plan

Write the service, the packed weight and the outer dimensions. Note whether the pack is regular, flat, elongated or a soft pack, because the published outline lists different checks for some of those forms.

Ask the current procedure from FedEx or from the lab, including the order of the tests. Then decide which steps you will run in house, and which steps you will send out.

Frequently asked questions

If my box passes a compression test, will FedEx accept the pack?

Not on the strength of that one check. The official programme lists more than compression, and acceptance is a matter between you and the carrier.

Can you run the official FedEx sequence in our factory as a certified test?

This article does not make that offer. Please confirm with us what we can actually run on the instruments we sell.

Is ISTA 6-FedEx still the document to follow?

ISTA's public page says those 6-Series FedEx procedures are no longer ISTA 6-Series tests. Check the current FedEx and ISTA instructions before you write a method number into a specification.