Box Compression Test Standards ASTM D642 ISO 12048 and TAPPI T 804
By Lim Xu, Export Manager
The main box compression test standards are ASTM D642, ISO 12048 and TAPPI T 804. All three measure how well a shipping container resists compressive load in a compression machine. They differ in scope, in how contents are treated and in what they ask you to control and report.
Which standards cover box compression testing
ASTM D642 states that it is related to TAPPI T 804 and that it fulfills the requirements of ISO 12048. It also warns that the ISO method may not meet the requirements of D642, so the link only runs one way.
The table below compares what each method covers, based on the public scope text of each standard.
| Standard | What it tests | Empty or filled | Load direction |
|---|---|---|---|
| ASTM D642 | Shipping containers, components and unit loads | With or without contents | Faces, opposite edges or corners |
| ISO 12048 | Complete, filled transport packages | Normally filled with the intended contents | A set attitude; edges or corners with non-tilting platens |
| TAPPI T 804 | Corrugated or solid fiber shipping containers | Empty, with inner packing, or fully packed | Top to bottom, end to end or side to side |
Of the three, D642 has the widest scope, ISO 12048 is written around filled packages, and T 804 covers fiberboard containers.
ASTM D642 at a glance
ASTM D642 covers compression tests on boxes, drums and other shipping containers, their components, and unit loads. You can use it to compare a container design with a standard, or to compare containers built in different ways.
The machine can have fixed or swiveled platens. Edge to edge and corner to corner tests need a fixed head, and unit loads are generally tested top to bottom only.
Platen type changes the result. D642 notes that fixed platens generally make a corrugated box fail at its strongest point, while a swiveled platen moves to its weakest point.
For a constant load test, D642 refers you to ASTM D4577.
Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].
ISO 12048 at a glance
ISO 12048 sets out two tests on complete, filled transport packages using the same apparatus. One is a compression test to failure or to a set load or displacement. The other is a stacking test under a set load.
The motor driven tester closes the platens at 10 mm/min ± 3 mm/min, moving one or both of them. The standard does not recommend comparing these results with results from machines run at other speeds, such as 12.5 mm/min.
The package should hold its intended contents, or dummy contents as close as possible to them in size and physical properties. It should be closed the same way it would be for distribution.
Conditioning follows ISO 2233, which lists several atmospheres to choose from. Where conditions matter for the package, the test should run in the same atmosphere used for conditioning.
TAPPI T 804 and conditioning
TAPPI T 804 measures how well corrugated and solid fiber shipping containers resist outside compressive forces. For quality studies, testing the empty container is usually preferred.
Where inner packing such as corner posts carries load, test with that packing in place. To study the whole pack, test the container filled with its contents and all inner packing, because they often share part of the load.
The public summary of T 804 does not give the conditioning atmosphere. In North America, TAPPI T 402 defines the standard atmospheres for conditioning and testing paper, board, fiberboard and containers made from them. Internationally, ISO 187 does the same for paper and board.
ISO 187 notes that the physical properties of paper depend on its moisture content, so record the atmosphere every time. Our KY-2 carton compression tester is built for whole carton tests; ask us which methods it is set up for before you choose.
Choosing a standard for your customer
Start with the method your customer names. If a specification calls for ASTM D642, a test run only to ISO 12048 may not satisfy it. D642 itself says the ISO method may not meet its requirements.
When a customer accepts more than one method, choose by what you need to learn:
- Board or box quality from empty containers: TAPPI T 804 or ASTM D642
- Filled packages, including a stacking test under a held load: ISO 12048
- Drums, components or unit loads: ASTM D642
- Edge or corner loading: ASTM D642 or ISO 12048, on a fixed head machine
Whichever you pick, keep it fixed when comparing suppliers or designs. An ISO 12048 report states the package attitude, the conditioning, the apparatus type, whether both platens were rigid and the loading rate.
Frequently asked questions
Does a box compression test standard set a pass or fail value?
No. These methods describe how to load a container and what to record. The pass level comes from your customer's specification or your own design target, and the standard method is then used to check against it.
Is a stacking test the same as a compression test?
No. In ISO 12048, a compression test raises the load until failure or a set value. A stacking test holds a set load for a set time or until collapse, and the held load may vary by no more than ±4%.
How many boxes should I test?
ISO 12048 asks for five replicate packages when possible. For ASTM D642 and TAPPI T 804, take the number from the full method or your customer's specification, and record it in the report.
Talk to our factory team
We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].
Related articles
- Tensile Strength of Paper and How to Test It under ISO 1924Tensile strength of paper is the peak force per unit width before a strip breaks. See kN/m and tensile index units and ISO 1924-2 test setup.
- How to Measure Water Vapor Transmission Rate of Packaging FilmHow to measure water vapor transmission rate of film: cup, infrared and electrolytic methods, the conditions that matter and a worked WVTR calculation.
- Box Compression Test Formula and the McKee EquationThe box compression test formula most labs use is the simplified McKee equation. See each term, a worked ECT to BCT example and when to test boxes instead.
- FedEx Packaging Test Standards for Parcel ShippersWhat FedEx lists for small-parcel tests, and which of those checks map to carton compression equipment on this site. No unsold drop testers.
